1039 Goodwin Drive. Suite 100 Lexington, KY. 40505 |
Ph: 859-225-0051 Fx: 859-225-0054 |
Reliable
Automation
Devices
A Distribution Company
|
Laser and Measurement Sensors
| Analogue sensors | ![]() |
![]() |
![]() |
![]() |
![]() |
| Type | FT 20 RA | FT 50 RLA-20 | FT 50 RLA-40 | FT 50 RLA-70 | FT 50 RLA-220 |
| Features | Analogue sensor Schaltfenster Dynamic Teach In (by button or control input) Lock function |
Analogue laser sensor Precise potentiometer setting Contamination indicator |
Analogue laser sensor Precise potentiometer setting Contamination indicator |
Analogue laser sensor Threshold function Master/Slave function Precise even with reflecting objects |
Analogue laser sensor Threshold function Master/Slave function Precise even with reflecting objects |
| Working distance | 20 ... 80 mm | 40 ... 60 mm | 45... 85 mm | 30 ... 100 mm | 80 ... 300 mm |
| Switching frequency | 200 Hz | 80/800 Hz | 80/800 Hz | 1.000 kHz | 1.000 kHz |
| Signal output | Analogue 0 ... 10V/PNP |
Analogue 0 ... 10 V |
Analogue 0 ... 10 V |
Analogue/PNP | Analogue/PNP |
| Light spot diameter | 5 x 5 mm (d = 60 mm) | <0,8 mm | <0,8 mm | 2 x 4 mm | 2 x 4 mm |
| Resolution | 0,5 mm | 0,04 mm/ 0,007 mm |
0,08 mm/ 0,02 mm |
0,1 mm | 0,3 mm |
| Download | Data sheet(d/e/f) | Data sheet(d/e) | Data sheet(d/e) |
|
| Analogue sensors | ![]() |
![]() |
![]() |
![]() |
![]() |
| Type | FT 91 | FT 90 | FR 91 | FR 90 | FSEG |
| Features | Distance sensor High repeatability High measuring rates Open interfaces for maximum compatibility |
Distance measuring device High repeatability High measuring rates Open interfaces for maximum compatibility |
Distance sensor High repeatability High measuring rates Open interfaces for maximum compatibility |
Distance measuring device High repeatability High measuring rates Open interfaces for maximum compatibility |
Ultra flat housing 20 x
40 mm resolution 4 mm response time 1 ms |
| Working distance | 0,5 ... 6 m | 0,5 ... 10 m | 0,5 ... 50 m | 0,5 ... 250 m | Red, 660 nm, pulsed |
| Response time/ Switching frequency |
12 ms | 12 ms | 12 ms | 12 ms | 1000 Hz |
| Signal output | 2 x PNP 0 ... 20 mA RS 422, SSI |
2 x PNP 0 ... 20 mA RS 422, SSI |
2 x PNP RS 422, SSI |
2 x PNP RS 422, SSI |
Analogue/PNP 0 ... 10 V |
| Light spot diameter | 4 mm x 12 mm @ 6 m | 4 mm x 12 mm @ 6 m | 20 mm x 20 mm @ 10 m | 20 mm x 20 mm @ 10 m | |
| Repetition accuracy | +/- 5 mm | +/- 4 mm | +/- 5 mm | +/- 2 mm | +/- 3,5 ... +/- 7 mm |
| Download | Manual | Manual | Manual | Manual | Data Sheet |